این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Frontiers in Biomedical Technologies، جلد ۱۰، شماره ۲، صفحات ۱۹۵-۲۰۳

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Realizing 32-time Scan Duration Reduction of 18F-FDG PET Using Deep Learning Model with Image Augmentation
چکیده انگلیسی مقاله Purpose: 32-time scan duration reduction of 18F-FDG Positron Emission Tomography (PET) images through the generation of standard scan duration images using a multi-slice cycle-consistent Generative Adversarial Network (cycle-GAN) was studied. Also, the effect of the image augmentation methods on the performance of the cycle-GAN model was evaluated. Materials and Methods: Four subsets of standard and 32-time short scan duration PET image pairs, each contacting image data of 10 patients were used to train and test (80 percent for training and 20 percent for testing) a multi-slice cycle-GAN separately. Another patient’s image data was used as the validation dataset for different training subsets. When training the cycle-GAN model for each subset, two approaches were followed: with and without image augmentation. Common image quality metrics of PSNR, SSIM, and NRMSE were used to assess the generation performance of the cycle-GAN model. Paired sample t-test statistical testing with a confidence interval of 0.95 was used to determine whether the differences between approaches were statistically significant or not. Results: For subsets 1-3, both training approaches improved the image quality of the short scan duration inputs (p< 0.001) while for subset 4 only the training approach with image augmentation was capable of improving the image quality. However, the training approach with image augmentation offered better results than the approach without image augmentation (p< 0.001). Conclusion: Employing the training approach with image augmentation, the cycle-GAN model was capable of improving the image quality of 1/32nd short scan duration images through the generation of synthetic standard scan duration images. In the case of the training approach without image augmentation, except for subset 4, the model trained on all subsets 1-3 was capable of improving the image quality. Image augmentation does indeed improve the performance of the cycle-GAN model, especially in the case of insufficient available training datasets.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | Ali Ghafari
Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran


| Peyman Sheikhzadeh
Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran


| Negisa Seyyedi
Nursing Care Research Center, Iran University of Medical Sciences, Tehran, Iran


| Mehrshad Abbasi
Department of Nuclear Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran


| Mohammad Reza Ay
Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran



نشانی اینترنتی https://fbt.tums.ac.ir/index.php/fbt/article/view/495
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات